Case Studies and Stories
Turning Early Detection into 9,300 Tons of Saved Production
A subtle change in vibration was the only early warning, but it was enough to make a major difference. By acting on advanced diagnostics and continuous condition monitoring, a fertilizer plant in France avoided unplanned downtime and saved 9,300 tons of production. This case study shows how early detection, paired with expert analysis, turns potential failure into operational advantage.
- Nicolas Bourdier, Khalid Achtal, Miguel Fernandez Sanz, Peter Popaleny
- Baker Hughes
Vibration Analysis Report of Chilled Water Pump
Due to unexpectedly high vibration levels in a newly commissioned chilled water pump located at Tampines Mall, Alstern Technologies Singapore Pte Ltd engaged SPM to conduct a comprehensive vibration analysis. This analysis involved on-site testing, including run-up and coast-down tests.
- Aung Zay Yar Min
- SPM Instrument
Vibration Spectrum Analysis on Chiller Unit
A call for vibration survey was performed to identify vibratory force that has within the chiller motor and compressor at different vibration location on system.
- Aung Zay Yar Min
- SPM Instrument
Report of Smoke Exhaust Fans’ Vibration Measurement
Vibration measurement is a technique employed to identify and assess the magnitude of vibration in machinery or mechanical systems. It is an important technique in predictive maintenance and can help diagnose faults, especially in the early stages.
- Aung Zay Yar Min
- SPM Instrument
Avoiding Unplanned Downtime: Online Monitor of Critical Bearings
Keeping a close eye on the condition of critical equipment is fundamental in any industrial facility. When critical bearings fail, it almost always leads to unplanned downtime and interrupted production process, costing companies thousands in production loses. In this case study we will look at how an online monitoring solution using ultrasonic sensors was able to detect an issue on a critical bearing before it turned into a big problem.
- Peter Boon
- UE Systems Inc.
Modification on Structure Foundation to Mitigation Resonance Region of Gland Steam Blowers
The Gland steam system is one of the most important systems in the work of the steam turbine, that have function to prevents steam escaping to atmosphere from the HP end of the turbine, and loss of vacuum from the LP end.
- Ahmad Alfakeer
- SEPCO
Why Use ESA? Windpower Case Study
Howard Penrose explains Electrical Signature Analysis (ESA) and how the different parts of 1.6 megawatt GE towers contribute to generating wind power.
- Howard Penrose
- MotorDoc LLC
Case Study: Cooling Tower Vibration Monitoring
Cooling towers are a critical component in many process facilities and contain several pieces of rotating machinery that contribute to their operation. Motors, gearboxes, fans and shafts require vibration monitoring to provide technicians with early warning signs of impending failures that could lead to catastrophic breakdowns.
- Peter Eitnier
- Wilcoxon Sensing Technologies
Compressed Air Survey leak & Energy Saving Case Study
Compressed Instrument air System is a vital system for the operation of steam and gas turbine control systems like (pneumatic equipment, valves & electrical controls.
….) Therefore, it is important to make it work efficiently and effectively without any problems that might affect its operation & Performance.
- Ahmad Alfakeer
- SEPCO
- 1